• Home
  • FM200 Clean Agent Fire Extinguishing Tank

FM200 Clean Agent Fire Extinguishing Tank

FM200 Clean Agent Fire Extinguishing Tank
by:admin June 2, 2025 0 Comments

FM200 Clean Agent Fire Extinguishing Tank widely adopted across critical applications such as data centers, telecom facilities, military vehicles, museums, and medical labs. Recognized for its efficiency, safety, and zero residue, FM-200® extinguishes fires rapidly without causing harm to sensitive equipment or the environment. It is the most trusted halon alternative and complies with NFPA 2001 and other global safety standards.


FM200 Clean Agent Fire Extinguishing Tank (HFC-227ea)

The clean agent fire extinguishing tank stores HFC-227ea under pressure. Upon fire detection, an impulse valve opens to discharge the agent rapidly through a network of pipes and nozzles. The clean agent extinguishes the fire by breaking the chemical reaction of the combustion process while leaving no residue, making it ideal for electronics and archival materials.


Key Components of FM200 Clean Agent Fire Extinguishing Tank

1. 02-03 Selector Valves

Selector valves allow a single agent storage container to protect multiple enclosures or hazard zones, significantly reducing the total agent quantity required. This leads to cost-effective fire suppression and a more compact system design.

2. 02-04 Instructional Signs

Instructional signs are essential for guiding personnel during emergencies and maintaining compliance with NFPA 2001 and ANSI Z535 standards. Fike provides high-visibility, flame-retardant Lexan™ polycarbonate signs, designed specifically for the UK fire safety market.

3. 02-05 Agent Storage Containers with HFC-227ea

These containers are equipped with fast-acting impulse valves that rupture a sealed disc to release HFC-227ea upon receiving a manual, electric, or pneumatic signal. The container design ensures rapid discharge and consistent pressure across the system.

4. 02-06 HFC-227ea Clean Agent

HFC-227ea is a non-conductive, odorless, and colorless gas ideal for fire suppression in areas with electronics. It has a low toxicity level, making it safe for occupied spaces, and leaves no cleanup residue. Applications range from control rooms to chemical storage and power generation facilities.


FM200 Clean Agent Fire Extinguishing Tank Accessories and Add-ons

IV.1.03.01 – Engineered Nozzles

Fike’s engineered aluminum nozzles provide uniform distribution of the clean agent, ensuring consistent concentration levels throughout the protected area. They feature a corrosion-resistant anodized gray finish.

IV.1.04.01 – Instructional Signs

These signs meet ANSI Z535 and NFPA 2001 requirements, with caution labels and fire instructions made from flame-retardant polycarbonate. Easy to mount with adhesive backing, they are essential for safety compliance.

DIVA (Direct Impulse Valve Actuator)

The DIVA unit is a manual or electric actuator used to open the impulse valve by extending a piston that ruptures the disc, allowing agent discharge. It plays a crucial role in reliable system activation.

02-02 – Impulse Valve Pneumatic Operator Kit (IVPO)

The IVPO kit pneumatically activates the Fike Impulse Valve, delivering fast and reliable fire suppression in applications where manual or electric activation isn’t feasible.

IV.1.11.01 – Impulse Check Valve

Check valves prevent the backflow or loss of agent when containers are removed for servicing, ensuring system integrity and safety at all times.

IV.1.12.01 – Discharge Pressure Switch

This switch provides a pneumatic confirmation signal to the control panel, indicating successful discharge of the clean agent and helping ensure system accountability.

IV.1.13.01 – Low Pressure Switch

The optional Low Pressure Switch (LPS) monitors container pressure to detect a leak or low-pressure condition, allowing for early maintenance and system reliability.

IV.1.14.01 – Impulse Valve (1″ and 3″)

These rupture disc-based valves provide rapid discharge and precise agent release, crucial for effective fire suppression. Their size is selected based on hazard volume and system design.

IV.1.18.01 – Mounting Straps and Brackets

Designed for secure installation, these accessories help safely mount FM-200® tanks to various surfaces, ensuring structural stability in case of fire or seismic activity.

IV.1.19.01 – Pipes and Fittings

All system piping and fittings conform to NFPA 2001 standards, ensuring durability, reliability, and compatibility with high-pressure clean agent discharges.

IV.1.20.01 – Liquid Level Indicator (LLi)

The LLi device lets technicians verify the agent quantity in the container without removing it, simplifying routine maintenance and inspections.


Reset Multi-Tool for DIVA and UVO Units

The Reset Multi-Tool is used to reset actuators after a discharge or maintenance operation, ensuring the system is quickly returned to operational status.


Why Choose FM200 Clean Agent Fire Extinguishing Tank ?

  • Zero residue – no damage to sensitive equipment
  • Fast discharge – suppresses fire in 10 seconds or less
  • Safe for personnel – low toxicity, suitable for occupied spaces
  • Global compliance – meets NFPA 2001, ISO, and local standards
  • Minimal downtime – no clean-up required post-discharge

Conclusion

For advanced, reliable, and environmentally friendly fire protection, the FM200 Clean Agent Fire Extinguishing Tank is the premier solution. Backed by Fike’s robust components like impulse valves, selector valves, and instructional signs, this system is perfect for modern high-risk, mission-critical environments.

Categories:

Leave Comment