• Home
  • Booster Set And Break Tank

Booster Set And Break Tank

Booster Set And Break Tank
by:admin February 27, 2025 0 Comments

Booster Set And Break Tank are essential components in water boosting systems. They ensure a consistent supply of water and maintain pressure, especially in commercial and industrial applications. This guide provides an overview of the available booster set and break tank combinations, along with their materials, options, and features.

Booster Set and Break Tank Combinations: Base Mounted Sets

Base-mounted booster sets come in different configurations to meet varying water supply needs. These systems are available in both single-pump and twin-pump options.

Single or Twin Pump (Single Pump Only on 55lt and 91lt Tank Sets)

  • Single Pump: Ideal for smaller tank sizes, such as 55lt and 91lt. A single pump is perfect for applications with lower water demand.
  • Twin Pump: Available for larger systems, twin pumps provide added reliability. They ensure continuous operation if one pump fails, making them ideal for higher demand.

Variable or Fixed Speed

You can choose between variable speed or fixed speed pumps based on your system’s needs:

  • Variable Speed: These pumps adjust according to water demand. They optimize energy use while maintaining consistent pressure.
  • Fixed Speed: Fixed-speed pumps run at a constant speed, ideal for steady and predictable water pressure needs.

e-SV Vertical Multistage Pumps and e-HM Horizontal Pumps

Booster sets come with two types of pumps:

  • e-SV Vertical Multistage Pumps: These pumps are efficient, compact, and provide high pressure. They are perfect for applications with limited space or vertical installations.
  • e-HM Horizontal Pumps: These robust pumps are designed for larger-scale systems, providing reliable water flow in horizontal installations.

Tank Nominal Volumes Available:

  • 55lt, 91lt, 250lt, 450lt, 680lt, 1000lt for base-mounted sets.

Booster Set and Break Tank Combinations: Frame Mounted Sets

Frame-mounted booster sets offer larger tanks and more flexibility. These systems accommodate higher water demands and offer additional pump configurations.

Single or Twin Pump with Three Pumps Available on Larger Break Tank Sizes

  • Single Pump: Suitable for small to medium applications with a steady water supply.
  • Twin Pump: Perfect for medium to large installations where redundancy and reliability are essential.
  • Three Pumps: For larger systems, three pumps handle high water demand efficiently. They ensure system reliability even if one pump fails.

Variable or Fixed Speed

Just like the base-mounted sets, frame-mounted sets offer the option of variable speed or fixed speed pumps. This flexibility lets you select the most suitable system for your needs.

e-SV Vertical Multistage Pumps and e-HM Horizontal Pumps

Both types of pumps, e-SV vertical multistage and e-HM horizontal, are available for these larger systems. Depending on your specific installation, you can choose the most appropriate pump to meet your water boosting needs.

Tank Nominal Volumes Available:

  • 250lt, 450lt, 680lt, 1000lt, 1370lt, 1500lt, 2000lt, 3000lt for frame-mounted sets.

Ball Valve Housings for Optimal Tank Use

All tanks larger than 250lt come with ball valve housings. These housings maximize the usable volume of the tank, ensuring optimal water storage and performance.

Materials Used in Booster Set and Break Tank Combinations

The materials of the booster sets and tanks influence the durability and performance of the system. Here are the materials used:

  • 55lt and 91lt Bases: These bases are made from galvanized steel, offering strength and corrosion resistance.
  • Bases Above 91lt: Made from mild steel and painted in Lowara blue to provide extra protection.
  • 55lt and 91lt Tanks: Manufactured from UN-insulated polyethylene, these tanks help maintain water quality.

250-3000lt One-Piece Tanks

  • GRP (Glass Reinforced Plastic): These tanks are made from GRP, pre-insulated with 25mm PU foam (polyurethane). This insulation helps maintain water temperature and prevents freezing.
  • Polyester Gel Coat: The tank’s outer surface is coated with a protective gel coat.
  • Pipework: Tanks have copper pipework up to 50mm, and PVC pipework for sizes above 50mm.

Options Available with GRP Tanks

If you choose a GRP tank, several options can further optimize your system:

  • Delayed Action Ball Valves (Aylesbury Type K): These valves regulate water flow and prevent back flow.
  • Equilibrium Ball Valves (28-100mm): These valves help balance water inflow and outflow, improving tank performance.
  • 50mm Insulation: Additional insulation for enhanced temperature control.
  • Central Division in Tank: This divides the tank into sections, providing more efficient water management.
  • High-Level Switch: A high-level switch alerts you when the water level reaches a predetermined height.
  • Temperature Gauge: Monitors the water temperature to ensure it stays within the desired range.
  • Contents Gauge: Provides real-time information about the water level in the tank.

Break Tank Selector Switches

For systems with break tanks split into two sections, you can opt for break tank selector switches. These switches ensure water is directed to the appropriate tank section, optimizing water flow and storage.

Conclusion

Booster Set And Break Tank Choosing the right combination depends on your water supply needs. Whether you opt for base-mounted sets or frame-mounted sets, you have flexibility in choosing tank sizes, pump types, and speed configurations. The availability of GRP tanks, along with various valve options and insulation, ensures that your system will perform efficiently and reliably. By considering your specific water boosting requirements, you can create an optimized system that ensures reliable water flow, pressure, and storage.

Categories:

Leave Comment